STERIS Corporation
www.steris.com
(440) 392-7421 |
|
Chemical Indicators |
|
Class I process indicator |
|
Verify
Process Indicators |
|
Sterilization process compatibility |
|
Steam -Terminal |
|
Steam - Flash |
|
EO |
|
Vaporized Hydrogen Peroxide |
|
Peracetic acid |
|
Number of years company has offered this
device: |
|
12 years |
|
Special features, options, additional
product info |
|
The Verify Process Indicators provide
indication that a sterilization process has occurred. The Verify process
indicators may be used in a variety of sterilization processing systems,
including STERIS’ SYSTEM 1 Sterile Processing System and the NEW Amsco
V-PRO 1 Low Temperature Sterilization System. |
|
Class II Bowie-Dick test indicator |
|
Verify
Bowie Dick Test Pack |
|
Sterilization process compatibility |
|
Steam - Terminal |
|
Steam - Flash |
|
Number of years company has offered this
device: |
|
3 years |
|
Special features, options, additional
product info |
|
The VerifyBowie Dick Test Pack consists
of a series of barriers into which an indicator sheet has been embedded.
The pack’s design challenges a prevacuum steam sterilizer’s ability to
remove air and replace it with steam. The Verify Bowie Dick Test Pack is
unique in its ability to detect problems with steam quality and give
evidence of the root cause. |
|
Class IV multi-parameter indicator: |
|
Verify
MPI Steam Indicator |
|
Sterilization process compatibility |
|
Steam - Terminal |
|
Steam - Flash |
|
Number of years company has offered this
device: |
|
3 years |
|
Special features, options, additional
product info |
|
The Verify
MPI Steam Indicators are Class 4 multi-parameter indicators for steam
sterilization. Each indicator contains an ink spot on either end that
indicates steam has penetrated for a specified period of time. The
indicator strip may be torn in half and each half used as a chemical
indicator. |
|
Class V integrating indicator: |
|
Verify
Integrating Indicator |
|
Sterilization process compatibility |
|
Steam - Terminal |
|
Steam - Flash |
|
Number of years company has offered this
device: |
|
New this year |
|
Special features, options, additional
product info |
|
The Verify Integrating Indicators are
Class 5 integrating indicators for steam sterilization. The pass/fail
line located within the indicator window provides an easy read. When
placed in every item to be sterilized, it verifies that sterilization
parameters were achieved within the pack in a manner that correlates
with the “death” of a biological indicator. |
|
Class VI emulator: |
|
Verify
SixCessChallenge Packs, Indicators and Flash Indicators |
|
Sterilization process compatibility |
|
Steam - Terminal |
|
Steam - Flash |
|
Number of years company has offered this
device: |
|
New this year |
|
Special features, options, additional
product info |
|
The Verify
SixCesschallenge packs, indicators and flash indicator strips are
Class 6 emulating indicators. The easy-to-use indicators provide
immediate release of all loads, eliminating the need for segregation,
quarantining and emergency release. The cycle specificity gives a more
comprehensive sterilization monitoring method than other technologies
used today. Reduce the wait. Reduce the risk. Reduce the work. |
|
Biological Indicator |
|
Biological indicator |
|
Verify
Biological Indicators |
|
Sterilization process compatibility |
|
Steam - Terminal |
|
Steam - Flash |
|
EO |
|
Incubation time: |
|
24-48 hours |
|
Number of years company has offered this
device: |
|
12 years |
|
Special features, options, additional
product info |
|
The Verify
Self Contained Biological Indicators contain two species of bacterial
spores and may be used to monitor both steam and ethylene oxide
sterilization processes. Indicators come as self-contained biological
indicators, standard challenge packs and challenge packs that include a
Class 5 integrating indicator. A color change from blue to yellow
indicates that the parameters for sterilization were not achieved. |
Healthmark
Getinge
Raven
SPS Medical
STERIS
SteriTec
 |